Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

    • Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment
    • Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment
    • Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment
  • Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

    Product Details:

    Place of Origin: China
    Brand Name: Purescience
    Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
    Model Number: YE-TUF2000FP

    Payment & Shipping Terms:

    Minimum Order Quantity: 5 sets
    Price: USD150-USD900
    Packaging Details: carton
    Delivery Time: 3 weeks
    Supply Ability: 500 sets per month
    Contact Now
    Detailed Product Description
    Product Name: Ultrasonic Flowmeters Type: Inline | Pipe Type
    Accuracy: +/- 1% FS Operation: Key Boards
    Output Signal: 4-20 MA / OCT Pulse / Relay Input: 3-way 4-20 MA (temperature, Pressure And Level)
    Media Temperature: -30 - 160 ℃ Work Temperature: Converter: -20 - 60 ℃ ; Transducer: -30 - 160 ℃
    Pipe Diameter: 15 Mm - 6000mm Pipe Mount Material: Weld Steel, Stainless Steel, Cast Iron, Copper / Brass, Cement Pipe, Aluminum
    High Light:

    magnetic flowmeter

    ,

    electromagnetic flow meter

    Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

     

     

    Principle of operation

    This doppler inline ultrasonic flow meter, employs the frequency shift, that's the Doppler Effect, of an ultrasonic signal when it is reflected by suspended particles or gas bubbles (can be discontinusely) in motion. A metering technology uses the physical phenomenon of a sound wave which changes frequency when it is reflected by the moving discontinuities in a flowing liquid. The ultrasonic sound is transmitted into a pipe with flowing liquids, and the discontinuities reflect the ultrasonic wave with a slightly different frequency that is directly proportional to the rate of flow of the liquid (Figure 1). Current technology requires that the liquid contain at least 100 PPM of 100 micron or larger suspended particles or bubbles.

     

    Data sheet

    Items Performance & Parameter
    Convertor Principle Transit-time ultrasonic flow meter
    Accuracy + 1%
    Operation 4 keyboards operation
    Output signal 1 channel 4-20mA, resistance 0-1K , accuracy 0.1%
    1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)
    1 channel relay output
    Input signal 3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)
    Temperature transducer Pt100, heat / energy measurement
    Communication Galvanic isolation RS485, software upgrade by PC, MODBUS
    Signal cable Twisted-pair cable, 50m; RS485, transmission distance 1000m or above.
    Connect port Pipe material Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc
    Pipe Dia 15 - 6000 mm
    Straight pipe Upstream: 10xDia, or downstream: 5xDia, and 30xDia from pump
    Metering Liquid type

    Single sonic wave transmittable liquid, such as municipal water, cooling

    water,

    seawater water, waste water, pure water, Sewage with particle content, such

    as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

    heating, ventilation ,air conditioner, power plants,

      Temperature -30-160℃
      Turbidity Up to 10000 ppm and less bubble
      Flow velocity 0-7 m/s
    Work environment Temperature Convertor: -20-60 ℃, Transducer: -30-160℃
    Humidity Convertor: 85%RH, Transducer: submersible up to depth 2m
    Power supply DC8-36V or AC10-30V / 1.5W
    Dimension Convertor: 95*95*35mm

     

    Features:

    • Non-Intrusive, transducer for Most Pipes from DN32 to DN6000mm
    • Inline pipe type , insertion type or clamp on probe transducer for options
    • Wide Measuring Range of 0.05 to 9 mps
    • ±2% of Calibrated Span Accuracy
    • Configuration and Total Stored in SD
    • Protection IP65 for housing, IP68 for transducer

    Metering Diagram 

    Flow measurement                                                Heat measurement

    Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment 0Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment 1

    Reference chart

    Type

    Model

    Pipe dia (mm)

    Temperature

    Dimension (mm)

    Clamp on

    TS-2

    DN15-100

    -30-90℃

    45x25x32

    TM-1

    DN50-700

    -30-90℃

    64x39x44

    TL-1

    DN300-6000

    -30-90℃

    97x54x53

    Clamp on (high temperature)

    TS-2-HT

    DN15-100

    -30-90℃

    45x25x32

    TM-1-HT

    DN50-700

    -30-90℃

    64x39x44

    TL-1-HT

    DN300-6000

    -30-90℃

    97x54x53

    Insertion type

    TC-1

    DN80-6000

    -30-90℃

    190x80x55

    TC-2(lengthen)

    DN80-6000

    -30-90℃

    335x80x55

    Pipe type

    G3 (π type)

    DN15-25

    -30-160℃

     

    G2

    DN32/DN40

    -30-160℃

     

    G3

    DN50-6000

    -30-160℃

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Optional temperature transducer

    Specification

    Model

    Dia

    Temp.

    Water cut

    Accuracy

    Clamp-on temp. transducer Pt100

    CT-1

    >DN50

    -40-160℃

    No

    100+ 0.8℃

    Insertion temp. Transducer Pt100

    TCT-1

    Yes

    Insertion temp. Pt100 with pressure

    PCT-1

    No

    Insertion temp.Pt100 for small pipe D

    SCT-1

    <DN50

    Yes

     

     

     

     

     

     

    Industries

    • Chemicals
    • Petrochemicals
    • Oil & Gas
    • Heating, Ventilation & Air Conditioning (HVAC)
    • Power Plants
    • Water treatment

    Applications

    • Metering of cooling water
    • Demineralisedwater
    • Control of batching and blending operations
    • Mass flow measurement
    • Allocation measurement
    • District heating
    • Irrigation
    • Energy measurement

    Model Selection

    I

    Model

     

     

     

     

     

     

     

     

    YF

    Electromagnetic flowmeter

     

    TF

    Turbine

     

    VF

    Votex

     

    LX

    Vane wheel

     

    T

    Ultrasonic

     

     

    E/F display mode

    E: compact/local display, F: remote display

     

     

     

    Pipe Dia

    Type (mm)

     

     

     

    xxxx

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 

    400, 500, 600, 800, 1000

     

     

     

    Code

    Accuracy

     

     

     

    1

    + 0.5% FS

     

     

     

    2

    + 1.0% FS

     

     

     

    3

    + 0.2% FS

     

     

     

     

    Code

    Type

     

     

     

     

    N

    Converter: 12 / 24 VDC, pulse output

     

     

     

     

    A

    Transmitter: 24VDC, 4-20mA outpt

     

     

     

     

    B

    Intelligent, Lion battery, no local display

     

     

     

     

    G

    Smart, local display, 4-20mA output

     

     

     

     

    C1

    Smart, local display, RS485

     

     

     

     

    C2

    Smart, local display, HART

     

     

     

     

     

    Code

    Type

     

     

     

     

     

    S

    Carbon steel housing

     

     

     

     

     

    L

    Stainless steel housing

     

     

     

     

     

    G

    High pressure housing

     

     

     

     

     

    HL

    316L electrode

     

     

     

     

     

    HTi

    Titanium electrode

     

     

     

     

     

    HTa

    Tantlum electrode

     

     

     

     

     

    HC

    Hastelloy-C electrode

     

     

     

     

     

    L1

    Liquid media

     

     

     

     

     

    L2

    Gas media

     

     

     

     

     

    P

    Pressure compensation

     

     

     

     

     

    T

    Temperature compensation

     

     

     

     

     

    PT

    Pressure&Temp. Compensation

     

     

     

     

     

    F

    PTFE liner

     

     

     

     

     

    X

    Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F, 

    Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, 

    RS485, 316L electrode, liquid media meter, PTFE liner

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Competitive Advantage:

    • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
    • CE approval
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Calibration

    Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment 2

    Work shop

    Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment 3

    Contact Details
    Shanghai Xunhui Environment Technology Co., Ltd.

    Contact Person: Mr. Murphy

    Tel: +8613816614405

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products