Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsUltrasonic Flow Meters

Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS

Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS

    • Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS
    • Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS
  • Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS

    Product Details:

    Place of Origin: China
    Brand Name: Purescience
    Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
    Model Number: YE-TUF2000SWP

    Payment & Shipping Terms:

    Minimum Order Quantity: 5 sets
    Price: USD150-USD900
    Packaging Details: carton
    Delivery Time: 3 weeks
    Supply Ability: 500 sets per month
    Contact Now
    Detailed Product Description
    Product Name: Doppler Ultrasonic Flow Meter Type: Wall Mount, Insertion Type
    Accuracy: + / - 1%FS Operation: Key Boards
    Output Signal: 4-20 MA / OCT Pulse / Relay Input: 3-way 4-20 MA (temperature, Pressure And Level)
    Communication: RS485 / Modbus Power Supply: 8-36 VDC / 10-30 VAC
    Pipe Diameter: 15 Mm - 6000mm Pipe Mount Material: Weld Steel, Stainless Steel, Cast Iron, Copper / Brass, Cement Pipe, Aluminum
    High Light:

    magnetic flowmeter

    ,

    water flow meter

    Doppler wall mount ultrasonic Doppler flow meter, pipe type for pulp and paper | accuracy 1% FS 

     

    Generals

    The wall mount ultrasonic doppler flowmeters , can measure the flow of liquids that contain sound reflectors, suspended solids, or gas bubbles larger than 100 microns. It can automatically adjust filtering and gain settings to produce reliable readings in a wide range of liquid and reflector conditions.

    The flowmeters transmitt ultrasonic sound through the pipe wall, or from the probe inserted into the flowing liquid by the piezoelectric crystals contained in the transducer and probe tip. The sound wave, then be reflected by sonic reflectors suspended in the liquid, also recorded by the receiver. In case the sonic reflectors are moving within the sound transmission path, sound waves will be reflected at a frequency shifted, that's Doppler frequency, from the transmitted frequency. The difference between the 2 frequencies is directly proportional to the speed of the sonic reflectors, resulting in a liquid flow rate that is converted to various user-defined units.

     

    Data sheet

    Contents

    Technical parameters

    Data convertor

    Work Principle

    Doppler or transit-time ultrasonic flow meter

    Precision

    + 1%

    Panel

    4 keys panel

    Signal output

    single channel 4-20mA, resistance 0-1K , accuracy 0.1%

    single way OCT pulse (Pulse width: 6-1000ms, default: 200ms)

    single channel relay output

    Signal input

    Tri-way 4-20mA, accuracy: 0.1%, (temp., pressure, level)

    Temp. sensor Pt100, heat / energy measurement

    Interface

    Galvanic isolation RS485, software upgrade by PC, MODBUS

    Cable for signal

    Paired cable, 50m; RS485, transmission distance 1000m or above.

    Port connection

    Suitable pipe

    Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc

    Diameter

    DN15 - DN6000 mm

    Pipe straight

    Upstream: 10 D, downstream: 5 D, (30xDia from pump or valve)

    Measurement

    Media to measured

    Liquid is single sonic wave transmittable, such as municipal tap water, cooling 

    water,seawater, waste water, pure water, sewage with particle content,  oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals, heating, ventilation air conditioner, power plant

     

    Media temp.

    -30-160℃

     

    Turbidity

    Up to 10000 ppm and less bubble

     

    Flow rate

    0-7 m/s

    Work environment

    Temp.

    Transducer: -30-160℃, Convertor: -20-60 ℃,

    Humidity

    Transducer: submersible up to depth 2m, Convertor: 85%RH,

    Power supply

    DC8-36V or AC10-30V / 1.5W

    Dimension

    Convertor: 95*95*35mm

     

    Description:

    Its configuration includes the front-panel keypad, multi-line backlit LCD ( flow rate and total in user-selected units display). Power supply options include AC and DC. Output signal options are: 4 to 20 mA, relays, pulse.

    Transducers available with clamp-on and non-intrusive transducer for most metal or plastic pipes, high temperature and protection class. The operator can place these clamp-on transducers up to 305 m from the converter. The insertion probe transducer should be used on piping systems that do not permit ultrasonic penetration. It's inserted into the pipe wall and comes into direct contact with the flowing liquid.

    • Non-invasive clamp technology
    • Easy to install
    • No moving parts, leakage or corrosion, therefore no pressure drop
    • No pipe cutting or process interruption
    • Measurement independent of fluid properties
    • Bi-directional flow measurement

    Metering Diagram 

    Flow measurement                                                Heat measurement

    Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS 0

    Reference chart

    Type

    Model

    Pipe dia (mm)

    Temperature

    Dimension (mm)

    Clamp on

    TS-2

    DN15-100

    -30-90℃

    45x25x32

    TM-1

    DN50-700

    -30-90℃

    64x39x44

    TL-1

    DN300-6000

    -30-90℃

    97x54x53

    Clamp on (high temperature)

    TS-2-HT

    DN15-100

    -30-90℃

    45x25x32

    TM-1-HT

    DN50-700

    -30-90℃

    64x39x44

    TL-1-HT

    DN300-6000

    -30-90℃

    97x54x53

    Insertion type

    TC-1

    DN80-6000

    -30-90℃

    190x80x55

    TC-2(lengthen)

    DN80-6000

    -30-90℃

    335x80x55

    Pipe type

    G3 (π type)

    DN15-25

    -30-160℃

     

    G2

    DN32/DN40

    -30-160℃

     

    G3

    DN50-6000

    -30-160℃

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Optional temperature transducer

    Specification

    Model

    Dia

    Temp.

    Water cut

    Accuracy

    Clamp-on temp. transducer Pt100

    CT-1

    >DN50

    -40-160℃

    No

    100+ 0.8℃

    Insertion temp. Transducer Pt100

    TCT-1

    Yes

    Insertion temp. Pt100 with pressure

    PCT-1

    No

    Insertion temp.Pt100 for small pipe D

    SCT-1

    <DN50

    Yes

     

     

     

     

     

     

    Industries

    • Chemicals
    • Petrochemicals
    • Oil & Gas
    • Heating, Ventilation & Air Conditioning (HVAC)
    • Power Plants
    • Water treatment

    Applications

    • Metering of cooling water
    • Demineralisedwater
    • Control of batching and blending operations
    • Mass flow measurement
    • Allocation measurement
    • District heating
    • Irrigation
    • Energy measurement

    Model Selection

    I

    Model

     

     

     

     

     

     

     

     

    YF

    Electromagnetic flowmeter

     

    TF

    Turbine

     

    VF

    Votex

     

    LX

    Vane wheel

     

    T

    Ultrasonic

     

     

    E/F display mode

    E: compact/local display, F: remote display

     

     

     

    Pipe Dia

    Type (mm)

     

     

     

    xxxx

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 

    400, 500, 600, 800, 1000

     

     

     

    Code

    Accuracy

     

     

     

    1

    + 0.5% FS

     

     

     

    2

    + 1.0% FS

     

     

     

    3

    + 0.2% FS

     

     

     

     

    Code

    Type

     

     

     

     

    N

    Converter: 12 / 24 VDC, pulse output

     

     

     

     

    A

    Transmitter: 24VDC, 4-20mA outpt

     

     

     

     

    B

    Intelligent, Lion battery, no local display

     

     

     

     

    G

    Smart, local display, 4-20mA output

     

     

     

     

    C1

    Smart, local display, RS485

     

     

     

     

    C2

    Smart, local display, HART

     

     

     

     

     

    Code

    Type

     

     

     

     

     

    S

    Carbon steel housing

     

     

     

     

     

    L

    Stainless steel housing

     

     

     

     

     

    G

    High pressure housing

     

     

     

     

     

    HL

    316L electrode

     

     

     

     

     

    HTi

    Titanium electrode

     

     

     

     

     

    HTa

    Tantlum electrode

     

     

     

     

     

    HC

    Hastelloy-C electrode

     

     

     

     

     

    L1

    Liquid media

     

     

     

     

     

    L2

    Gas media

     

     

     

     

     

    P

    Pressure compensation

     

     

     

     

     

    T

    Temperature compensation

     

     

     

     

     

    PT

    Pressure&Temp. Compensation

     

     

     

     

     

    F

    PTFE liner

     

     

     

     

     

    X

    Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F, 

    Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, 

    RS485, 316L electrode, liquid media meter, PTFE liner

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Competitive Advantage:

    • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
    • CE approval
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Calibration

    Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS 1

    Work shop

    Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS 2

    Contact Details
    Shanghai Xunhui Environment Technology Co., Ltd.

    Contact Person: Mr. Murphy

    Tel: +8613816614405

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products