Send Message
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsUltrasonic Flow Meters

Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H

Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H

  • Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H
Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H
Product Details:
Place of Origin: China
Brand Name: Purescience
Certification: ISO9001 / ISO14001
Model Number: WH
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD300 - USD1000
Packaging Details: carton
Delivery Time: 2-3 weeks
Payment Terms: L/C, T/T, D/P
Supply Ability: 10000
Contact Now
Detailed Product Description
Flow Range: 0 - 335000 M3/h Accuracy: +/- 2.5% FS
Display: LCD, LED Ambient Temperature: -40 C - 55 C
Communication: RS232, RS485 Output: 4-20mA
Power Supply: 220V AC / 24V DC Power Consumption: <10W
Protection: IP65
Highlight:

electromagnetic flow meter

,

water flow meter

Ultrasonic open channel flow meters non contact sensor for sewage treatment plant STP 200m3/h

 

Product introduction

The Open channel Ultrasonic Flowmeter is a high precision flow measurement instrument, which use Transit Time Ultrasound principle to measure the flow in a variety of Flumes, Weirs or Troughs.

 

 

Features

 

  • With a fully independent intellectual property rights.
  • Has wide range of temperature compensation and original ERD interference intelligent identification system, measurement data stability, high precision.
  • Six groups flow condition all data sending 485 serial ports output, PC directly receive, decimal shows, the convenient user record and read archived.
  • Original "fluid flow correction system" that flow coefficient according to slot size and level to be automatic operation weir and timing compensation.
  • The blackout time time, the year/month/day/when/points/SEC, flow data, using the ferroelectric double backup storage 10 years off.
  • Original "measuring tank jam recognition alarm system" can detect liquid slag quality measurement slot throat and obstruction caused by measurement.
  • Precise date determined when the calendar clock Settings, display and cooperate with the memo and time axis to file information records.
  • Has 4~20 mA three wire system, RS485, switch quantity and so on many kinds of signal output function selection.
  • Using intelligent measuring high, digital calibration, the user installation calibration simple and quick.
  • The ultrasonic non-contact measurement with no moving parts, flow without components within, no block sensor fault hidden trouble.

Sensors

Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H 0Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H 1

                    Ultrasonic sensor                                                                                            Static pressure sensor

 

 

Main technical index

Model WH
Applicable weirs Right triangle weir slot (Open size: 500mm)
  Parshall flume (Larynx way width: 51mm, 76mm, 152mm, 228mm, 300mm)
  Rectangular weir (Opening size: 250mm, 500mm, 750mm )
Flow range depending on weirs dimensions to be used, up to 335000 m3/hr
Flow precision 5% FS
Level range 1m
Level precision 0.5% FS
Sensor blind area <300mm @ 25C
Output 4-20 mA, tri wires
Display

LCD display, include: four levels

four transient flow

Eight of the accumulative total flow

16 calendar clock

Work temperature 50C , customized available
Power supply AC220V
Outlet way Sensor leads 20m, instrument standard plugs
Installation instrument wall mount, sensor grain installation M68x2.0, or clamp on
Protection IP66 (sensor)

 

 

 

Applications
Measurement of water flow in Effluent, Waste Water, Rivers, Canals, Drains, Sewage, etc.


Flow Totalizer parameters
Flow measuring range: Depends on the size of the flume.
Maximum Count: 9999999999
Types of suitable weirs: Triangular weir, rectangular weir, Parshall flume, etc.
Display accuracy: 1 count. Overall accuracy depends on the input signal. Different Weirs /
flumes has different accuracies. A triangular weir has 1 to 2% flow error, a rectangular weir
has 1 to 4% accuracy, a Parshall flume has 3% flow error, etc.
Display: 2.8-inch LCD. Displays Height, Flowrate, Total Flow, etc.

 

Output
Voltage output: DC 12V or 24V
Signal output: RS485/RS232; 4~20mA; 2 channel relay

 

Troughs

Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H 2

Triangle weirs

Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H 3

Installation sample

Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H 4

 

Advantage

The production capacity is 20000 ultrasonic converter and 100,000 ultrasonic sensor.

Contact Details
Shanghai Xunhui Environment Technology Co., Ltd.

Contact Person: Mr. Murphy

Tel: 0086-138 1661 4405

Fax: 86-21-31105302

Send your inquiry directly to us (0 / 3000)