Turbine Water Meter With Positive Displacement Mechanism Cast Iron DN125 Hot Water 90 ℃

Turbine Water Meter With Positive Displacement Mechanism Cast Iron DN125 Hot Water 90 ℃

    • Turbine Water Meter With Positive Displacement Mechanism Cast Iron DN125 Hot Water 90 ℃
    • Turbine Water Meter With Positive Displacement Mechanism Cast Iron DN125 Hot Water 90 ℃
  • Turbine Water Meter With Positive Displacement Mechanism Cast Iron DN125 Hot Water 90 ℃

    Product Details:

    Place of Origin: China
    Brand Name: Purescience
    Certification: ISO 4064B, GB/T19001
    Model Number: LXLC125R

    Payment & Shipping Terms:

    Minimum Order Quantity: 200 pieces
    Price: USD30 - USD300
    Packaging Details: unit pack by brown box, pallet
    Delivery Time: 4-5 weeks
    Payment Terms: L/C, D/P, T/T
    Supply Ability: 2,800,000 sets per year
    Contact Now
    Detailed Product Description
    Product Name: Woltman Water Meter Drive: Turbine Type
    Port Size: DN50 - DN600 Pressure: PN16
    Signal: Pulse Emitter Accuracy: + / - 2% @ Cold Water
    Protection: IP65 Standard: ISO4064 , GBT778 , Q/320700JR05-2003
    Function: Totalizer , Flow Rate
    High Light:

    woltman flow meter

    ,

    totalizing water meter

    Turbine water meter with positive displacement mechanism Cast Iron DN125 hot water 90 ℃

     

    The Turbine Water Meters are used for applications, where flows are moderate to high, but occasionally low. For example, the measurement of potable cold or hot water in commercial and industrial services. The flow shall be in one direction.

     

    Operation:

     

    The rotor turns proportionately to the volume of water flowing through the meter by water flowing through the turbine section. A magnetic drive transmits the motion of rotor to a driven magnet located under the hermetically sealed reading register. To a gear train, the magnetic is connected, which translates the rotations into totalized volume and displayed on the dial register. Only moving parts are the rotor assembly and vertical shaft.

     

    Features

    • The vertical helix design, easily maintenance.
    • Magnetic driven, dry dial, clear reading
    • Full flow measuremeng
    • Wide measure range, Q3 is up to 250 m3/h
    • Initial flow Q3 is down 0.03m3/h
    • Technical data conform to international standard ISO 4064.

     

    Note:

    • Measuring accuracy conform to ISO 4064 class B standard..
    • Available with different length on request. Available in hot water meter on request.

    Working condition:

    • Water temperature:0.1℃~40℃( 0.1℃~90℃ for hot water meter)
    • Water pressure: ≤1.0Mpa

    Maximum Permissible Error:

    (1) in the lower zone from qmin inclusive up to but excluding qt is ±5%

    (2) in the upper zone from qt inclusive up to and including qs is ±2%

    (3) Hot water meter ±3%

     

    Data sheet

    Model

    Dia

    (mm)

    Class

    ISO4064

    Overload 

    flow (Qs)

    Permanent 

    flow (Qp)

    Transitional 

    flow (Qt)

    Min flow

    Qmin

    Min reading

    Max reading

    m3/h

    M3

    IXLC-50

    50

    A

    30

    15

    4.5

    1.2

    0.0002

    999,999

    B

    3.0

    0.45

    IXLC-65

    65

    A

    50

    25

    7.5

    2.0

    0.0002

    999,999

    B

    5.0

    0.75

    IXLC-80

    80

    A

    80

    40

    12

    3.2

    0.0002

    999,999

    B

    8.0

    1.2

    IXLC-100

    100

    A

    120

    60

    18

    4.8

    0.0002

    999,999

    B

    12

    1.8

    IXLC-125

    125

    A

    200

    100

    30

    8

    0.0002

    999,999

    B

    20

    3

    IXLC-150

    150

    A

    300

    150

    45

    12

    0.0002

    999,999

    B

    30

    4.5

    IXLC-200

    200

    A

    500

    250

    75

    20

    0.0002

    999,999

    B

    50

    7.5

    IXLC-250

    250

    A

    800

    400

    120

    32

    0.0002

    999,999

    IXLC-300

    300

    A

    1200

    600

    180

    48

    0.0002

    999,999

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Dimension (LXLC)

    Model

    Dia.

    L

    H

    Flange (mm)

    (mm)

    D1 (OD)

    D2 (hole)

    Bolt(n-M)

    IXLC-50

    50

    200

    253

    165

    125

    4-M16

    IXLC-65

    65

    200

    268

    185

    145

    4-M16

    IXLC-80

    80

    225

    284

    200

    160

    8-M16

    IXLC-100

    100

    250

    295

    220

    180

    8-M16

    IXLC-125

    125

    250

    310

    250

    210

    8-M16

    IXLC-150

    150

    300

    339

    285

    240

    8-M20

    IXLC-200

    200

    350

    382

    340

    295

    8-M20(1.0Mpa)

    12-M20(1.6Mpa)

    IXLC-250

    250

    400

    433

    395

    350

    12-M20(1.0Mpa)

    450

    438

    405

    355

    12-M24(1.6Mpa)

    IXLC-300

    300

    450

    483

    445

    400

    12-M20(1.0Mpa)

    500

    488

    460

    410

    12-M24(1.6Mpa)

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Competitive Advantage:

    • Compliance to international standards: ISO4064 / GBT778 / Q/320700JR05-2003
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

     

     

    Contact Details
    Shanghai Xunhui Environment Technology Co., Ltd.

    Contact Person: Mr. Murphy

    Tel: +8613816614405

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products