Place of Origin: | China |
Brand Name: | Purescience |
Certification: | ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429 |
Model Number: | TUF-2000P |
Minimum Order Quantity: | 5 sets |
---|---|
Price: | USD150-USD900 |
Packaging Details: | carton |
Delivery Time: | 3 weeks |
Supply Ability: | 500 sets per month |
Name: | Potable Ultrasonic Flow Meter | Type: | Potable |
---|---|---|---|
Operation: | Key Pad | Printer: | Yes |
Output Signal: | 4-20 MA / OCT Pulse / Relay | Input: | 3-way 4-20 MA (temperature, Pressure And Level) |
Communication: | RS485 / Modbus | Power Supply: | 8-36 VDC / 10-30 VAC |
Pipe Type: | Closed Pipe | Pipe Mount Material: | Weld Steel, Stainless Steel, Cast Iron, Copper / Brass, Cement Pipe, Aluminum |
Accuracy: | + / - 1%FS | ||
High Light: | magnetic flowmeter,water flow meter |
portable ulstrasonic flow meters for volumetric measurement non contact corrosion resistance
Product Description
Our potable ultrasonic flowmeter are widely used for liquids applications, including but not limited to the metering of cooling water and demineralised water, control of batching and blending operations, mass flow measurement, allocation
measurement, district heating, irrigation, energy measurement, effluent, etc.
Data sheet
Items |
Performance & Parameter |
|
Convertor |
Principle |
Transit-time ultrasonic flow meter |
Accuracy |
+ 1% |
|
Operation |
4 keyboards operation |
|
Output signal |
1 channel 4-20mA, resistance 0-1K , accuracy 0.1% |
|
1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms) |
||
1 channel relay output |
||
Input signal |
3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level) |
|
Temperature transducer Pt100, heat / energy measurement |
||
Communication |
Galvanic isolation RS485, software upgrade by PC, MODBUS |
|
Signal cable |
Twisted-pair cable, 50m; RS485, transmission distance 1000m or above. |
|
Connect port |
Pipe material |
Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc |
Pipe Dia |
15 - 6000 mm |
|
Straight pipe |
Upstream: 10xDia, or downstream: 5xDia, and 30xDia from pump |
|
Metering |
Liquid type |
Single sonic wave transmittable liquid, such as municipal water, cooling water, seawater water, waste water, pure water, Sewage with particle content, such as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals, heating, ventilation ,air conditioner, power plants, |
|
Temperature |
-30-160℃ |
|
Turbidity |
Up to 10000 ppm and less bubble |
|
Flow velocity |
0-7 m/s |
Work environment |
Temperature |
Convertor: -20-60 ℃, Transducer: -30-160℃ |
Humidity |
Convertor: 85%RH, Transducer: submersible up to depth 2m |
|
Power supply |
DC8-36V or AC10-30V / 1.5W |
|
Dimension |
Convertor: 95*95*35mm |
Description:
The pipe type inline ultrasonic flowmeter is a precision instrument designed for linear, bi/directional volumetric flow
measurement of liquids. Flow measurement values can be output via the standard analog and-or pulse/frequency
outputs. Through a user friendly operator interface (HMI) the unit can be set up for a wide range of applications.
Next to actual volumetric flow measurement the unit can be configuredto perform flow totalization (plus, minus and
sum). Also measurement and output of the liquid sonic velocity can be configured. Optionally the unit can be set to
perform one of the following additional functions:
Metering Diagram
Flow measurement Heat measurement
Reference chart
Type |
Model |
Pipe dia (mm) |
Temperature |
Dimension (mm) |
Clamp on |
TS-2 |
DN15-100 |
-30-90℃ |
45x25x32 |
TM-1 |
DN50-700 |
-30-90℃ |
64x39x44 |
|
TL-1 |
DN300-6000 |
-30-90℃ |
97x54x53 |
|
Clamp on (high temperature) |
TS-2-HT |
DN15-100 |
-30-90℃ |
45x25x32 |
TM-1-HT |
DN50-700 |
-30-90℃ |
64x39x44 |
|
TL-1-HT |
DN300-6000 |
-30-90℃ |
97x54x53 |
|
Insertion type |
TC-1 |
DN80-6000 |
-30-90℃ |
190x80x55 |
TC-2(lengthen) |
DN80-6000 |
-30-90℃ |
335x80x55 |
|
Pipe type |
G3 (π type) |
DN15-25 |
-30-160℃ |
|
G2 |
DN32/DN40 |
-30-160℃ |
|
|
G3 |
DN50-6000 |
-30-160℃ |
|
Optional temperature transducer
Specification |
Model |
Dia |
Temp. |
Water cut |
Accuracy |
Clamp-on temp. transducer Pt100 |
CT-1 |
>DN50 |
-40-160℃ |
No |
100+ 0.8℃ |
Insertion temp. Transducer Pt100 |
TCT-1 |
Yes |
|||
Insertion temp. Pt100 with pressure |
PCT-1 |
No |
|||
Insertion temp.Pt100 for small pipe D |
SCT-1 |
<DN50 |
Yes |
Industries
Applications
Model Selection
I |
Model |
|
|
|
|
|
|
|
|
|
YF |
Electromagnetic flowmeter |
|||||||
|
TF |
Turbine |
|||||||
|
VF |
Votex |
|||||||
|
LX |
Vane wheel |
|||||||
|
T |
Ultrasonic |
|||||||
|
|
E/F display mode |
E: compact/local display, F: remote display |
||||||
|
|
|
Pipe Dia |
Type (mm) |
|||||
|
|
|
xxxx |
10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 |
|||||
|
|
|
Code |
Accuracy |
|||||
|
|
|
1 |
+ 0.5% FS |
|||||
|
|
|
2 |
+ 1.0% FS |
|||||
|
|
|
3 |
+ 0.2% FS |
|||||
|
|
|
|
Code |
Type |
||||
|
|
|
|
N |
Converter: 12 / 24 VDC, pulse output |
||||
|
|
|
|
A |
Transmitter: 24VDC, 4-20mA outpt |
||||
|
|
|
|
B |
Intelligent, Lion battery, no local display |
||||
|
|
|
|
G |
Smart, local display, 4-20mA output |
||||
|
|
|
|
C1 |
Smart, local display, RS485 |
||||
|
|
|
|
C2 |
Smart, local display, HART |
||||
|
|
|
|
|
Code |
Type |
|||
|
|
|
|
|
S |
Carbon steel housing |
|||
|
|
|
|
|
L |
Stainless steel housing |
|||
|
|
|
|
|
G |
High pressure housing |
|||
|
|
|
|
|
HL |
316L electrode |
|||
|
|
|
|
|
HTi |
Titanium electrode |
|||
|
|
|
|
|
HTa |
Tantlum electrode |
|||
|
|
|
|
|
HC |
Hastelloy-C electrode |
|||
|
|
|
|
|
L1 |
Liquid media |
|||
|
|
|
|
|
L2 |
Gas media |
|||
|
|
|
|
|
P |
Pressure compensation |
|||
|
|
|
|
|
T |
Temperature compensation |
|||
|
|
|
|
|
PT |
Pressure&Temp. Compensation |
|||
|
|
|
|
|
F |
PTFE liner |
|||
|
|
|
|
|
X |
Rubber liner |
|||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrode, liquid media meter, PTFE liner |
Competitive Advantage:
Calibration
Work shop
Contact Person: Mr. Murphy
Tel: +8613816614405