Product Details:
Place of Origin: China
Brand Name: Purescience
Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Model Number: YE-TUF2000FP
Payment & Shipping Terms:
Minimum Order Quantity: 5 sets
Price: USD150-USD900
Packaging Details: carton
Delivery Time: 3 weeks
Supply Ability: 500 sets per month
Contact Now
Detailed Product Description
Product Name: Ultrasonic Flowmeters Type: Inline | Pipe Type
Accuracy: +/- 1% FS Operation: Key Boards
Output Signal: 4-20 MA / OCT Pulse / Relay Input: 3-way 4-20 MA (temperature, Pressure And Level)
Media Temperature: -30 - 160 ℃ Work Temperature: Converter: -20 - 60 ℃ ; Transducer: -30 - 160 ℃
Pipe Diameter: 15 Mm - 6000mm Pipe Mount Material: Weld Steel, Stainless Steel, Cast Iron, Copper / Brass, Cement Pipe, Aluminum
Highlight:

magnetic flowmeter

,

electromagnetic flow meter

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

 

 

Principle of operation

This doppler inline ultrasonic flow meter, employs the frequency shift, that's the Doppler Effect, of an ultrasonic signal when it is reflected by suspended particles or gas bubbles (can be discontinusely) in motion. A metering technology uses the physical phenomenon of a sound wave which changes frequency when it is reflected by the moving discontinuities in a flowing liquid. The ultrasonic sound is transmitted into a pipe with flowing liquids, and the discontinuities reflect the ultrasonic wave with a slightly different frequency that is directly proportional to the rate of flow of the liquid (Figure 1). Current technology requires that the liquid contain at least 100 PPM of 100 micron or larger suspended particles or bubbles.

 

Data sheet

Items Performance & Parameter
Convertor Principle Transit-time ultrasonic flow meter
Accuracy + 1%
Operation 4 keyboards operation
Output signal 1 channel 4-20mA, resistance 0-1K , accuracy 0.1%
1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)
1 channel relay output
Input signal 3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)
Temperature transducer Pt100, heat / energy measurement
Communication Galvanic isolation RS485, software upgrade by PC, MODBUS
Signal cable Twisted-pair cable, 50m; RS485, transmission distance 1000m or above.
Connect port Pipe material Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc
Pipe Dia 15 - 6000 mm
Straight pipe Upstream: 10xDia, or downstream: 5xDia, and 30xDia from pump
Metering Liquid type

Single sonic wave transmittable liquid, such as municipal water, cooling

water,

seawater water, waste water, pure water, Sewage with particle content, such

as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

heating, ventilation ,air conditioner, power plants,

  Temperature -30-160℃
  Turbidity Up to 10000 ppm and less bubble
  Flow velocity 0-7 m/s
Work environment Temperature Convertor: -20-60 ℃, Transducer: -30-160℃
Humidity Convertor: 85%RH, Transducer: submersible up to depth 2m
Power supply DC8-36V or AC10-30V / 1.5W
Dimension Convertor: 95*95*35mm

 

Features:

  • Non-Intrusive, transducer for Most Pipes from DN32 to DN6000mm
  • Inline pipe type , insertion type or clamp on probe transducer for options
  • Wide Measuring Range of 0.05 to 9 mps
  • ±2% of Calibrated Span Accuracy
  • Configuration and Total Stored in SD
  • Protection IP65 for housing, IP68 for transducer

Metering Diagram 

Flow measurement                                                Heat measurement

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment 0Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment 1

Reference chart

Type

Model

Pipe dia (mm)

Temperature

Dimension (mm)

Clamp on

TS-2

DN15-100

-30-90℃

45x25x32

TM-1

DN50-700

-30-90℃

64x39x44

TL-1

DN300-6000

-30-90℃

97x54x53

Clamp on (high temperature)

TS-2-HT

DN15-100

-30-90℃

45x25x32

TM-1-HT

DN50-700

-30-90℃

64x39x44

TL-1-HT

DN300-6000

-30-90℃

97x54x53

Insertion type

TC-1

DN80-6000

-30-90℃

190x80x55

TC-2(lengthen)

DN80-6000

-30-90℃

335x80x55

Pipe type

G3 (π type)

DN15-25

-30-160℃

 

G2

DN32/DN40

-30-160℃

 

G3

DN50-6000

-30-160℃

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional temperature transducer

Specification

Model

Dia

Temp.

Water cut

Accuracy

Clamp-on temp. transducer Pt100

CT-1

>DN50

-40-160℃

No

100+ 0.8℃

Insertion temp. Transducer Pt100

TCT-1

Yes

Insertion temp. Pt100 with pressure

PCT-1

No

Insertion temp.Pt100 for small pipe D

SCT-1

<DN50

Yes

 

 

 

 

 

 

Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

I

Model

 

 

 

 

 

 

 

 

YF

Electromagnetic flowmeter

 

TF

Turbine

 

VF

Votex

 

LX

Vane wheel

 

T

Ultrasonic

 

 

E/F display mode

E: compact/local display, F: remote display

 

 

 

Pipe Dia

Type (mm)

 

 

 

xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 

400, 500, 600, 800, 1000

 

 

 

Code

Accuracy

 

 

 

1

+ 0.5% FS

 

 

 

2

+ 1.0% FS

 

 

 

3

+ 0.2% FS

 

 

 

 

Code

Type

 

 

 

 

N

Converter: 12 / 24 VDC, pulse output

 

 

 

 

A

Transmitter: 24VDC, 4-20mA outpt

 

 

 

 

B

Intelligent, Lion battery, no local display

 

 

 

 

G

Smart, local display, 4-20mA output

 

 

 

 

C1

Smart, local display, RS485

 

 

 

 

C2

Smart, local display, HART

 

 

 

 

 

Code

Type

 

 

 

 

 

S

Carbon steel housing

 

 

 

 

 

L

Stainless steel housing

 

 

 

 

 

G

High pressure housing

 

 

 

 

 

HL

316L electrode

 

 

 

 

 

HTi

Titanium electrode

 

 

 

 

 

HTa

Tantlum electrode

 

 

 

 

 

HC

Hastelloy-C electrode

 

 

 

 

 

L1

Liquid media

 

 

 

 

 

L2

Gas media

 

 

 

 

 

P

Pressure compensation

 

 

 

 

 

T

Temperature compensation

 

 

 

 

 

PT

Pressure&Temp. Compensation

 

 

 

 

 

F

PTFE liner

 

 

 

 

 

X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, 

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, 

RS485, 316L electrode, liquid media meter, PTFE liner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Calibration

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment 2

Work shop

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment 3

Contact Details
Shanghai Xunhui Environment Technology Co., Ltd.

Contact Person: Mr. Murphy

Tel: 0086-138 1661 4405

Fax: 86-21-31105302

Send your inquiry directly to us (0 / 3000)

Best Products
Other Products