All Flow Technology
Place of Origin: | China |
Brand Name: | Purescience |
Certification: | ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429 |
Model Number: | YE-TUF2000FP |
Minimum Order Quantity: | 5 sets |
---|---|
Price: | USD150-USD900 |
Packaging Details: | carton |
Delivery Time: | 3 weeks |
Supply Ability: | 500 sets per month |
Product Name: | Ultrasonic Flowmeters | Type: | Inline | Pipe Type |
---|---|---|---|
Accuracy: | +/- 1% FS | Operation: | Key Boards |
Output Signal: | 4-20 MA / OCT Pulse / Relay | Input: | 3-way 4-20 MA (temperature, Pressure And Level) |
Media Temperature: | -30 - 160 ℃ | Work Temperature: | Converter: -20 - 60 ℃ ; Transducer: -30 - 160 ℃ |
Pipe Diameter: | 15 Mm - 6000mm | Pipe Mount Material: | Weld Steel, Stainless Steel, Cast Iron, Copper / Brass, Cement Pipe, Aluminum |
Highlight: | magnetic flowmeter,electromagnetic flow meter |
Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment
Principle of operation
This doppler inline ultrasonic flow meter, employs the frequency shift, that's the Doppler Effect, of an ultrasonic signal when it is reflected by suspended particles or gas bubbles (can be discontinusely) in motion. A metering technology uses the physical phenomenon of a sound wave which changes frequency when it is reflected by the moving discontinuities in a flowing liquid. The ultrasonic sound is transmitted into a pipe with flowing liquids, and the discontinuities reflect the ultrasonic wave with a slightly different frequency that is directly proportional to the rate of flow of the liquid (Figure 1). Current technology requires that the liquid contain at least 100 PPM of 100 micron or larger suspended particles or bubbles.
Data sheet
Items | Performance & Parameter | |
Convertor | Principle | Transit-time ultrasonic flow meter |
Accuracy | + 1% | |
Operation | 4 keyboards operation | |
Output signal | 1 channel 4-20mA, resistance 0-1K , accuracy 0.1% | |
1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms) | ||
1 channel relay output | ||
Input signal | 3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level) | |
Temperature transducer Pt100, heat / energy measurement | ||
Communication | Galvanic isolation RS485, software upgrade by PC, MODBUS | |
Signal cable | Twisted-pair cable, 50m; RS485, transmission distance 1000m or above. | |
Connect port | Pipe material | Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc |
Pipe Dia | 15 - 6000 mm | |
Straight pipe | Upstream: 10xDia, or downstream: 5xDia, and 30xDia from pump | |
Metering | Liquid type |
Single sonic wave transmittable liquid, such as municipal water, cooling water, seawater water, waste water, pure water, Sewage with particle content, such as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals, heating, ventilation ,air conditioner, power plants, |
Temperature | -30-160℃ | |
Turbidity | Up to 10000 ppm and less bubble | |
Flow velocity | 0-7 m/s | |
Work environment | Temperature | Convertor: -20-60 ℃, Transducer: -30-160℃ |
Humidity | Convertor: 85%RH, Transducer: submersible up to depth 2m | |
Power supply | DC8-36V or AC10-30V / 1.5W | |
Dimension | Convertor: 95*95*35mm |
Features:
Metering Diagram
Flow measurement Heat measurement
Reference chart
Type |
Model |
Pipe dia (mm) |
Temperature |
Dimension (mm) |
Clamp on |
TS-2 |
DN15-100 |
-30-90℃ |
45x25x32 |
TM-1 |
DN50-700 |
-30-90℃ |
64x39x44 |
|
TL-1 |
DN300-6000 |
-30-90℃ |
97x54x53 |
|
Clamp on (high temperature) |
TS-2-HT |
DN15-100 |
-30-90℃ |
45x25x32 |
TM-1-HT |
DN50-700 |
-30-90℃ |
64x39x44 |
|
TL-1-HT |
DN300-6000 |
-30-90℃ |
97x54x53 |
|
Insertion type |
TC-1 |
DN80-6000 |
-30-90℃ |
190x80x55 |
TC-2(lengthen) |
DN80-6000 |
-30-90℃ |
335x80x55 |
|
Pipe type |
G3 (π type) |
DN15-25 |
-30-160℃ |
|
G2 |
DN32/DN40 |
-30-160℃ |
|
|
G3 |
DN50-6000 |
-30-160℃ |
|
Optional temperature transducer
Specification |
Model |
Dia |
Temp. |
Water cut |
Accuracy |
Clamp-on temp. transducer Pt100 |
CT-1 |
>DN50 |
-40-160℃ |
No |
100+ 0.8℃ |
Insertion temp. Transducer Pt100 |
TCT-1 |
Yes |
|||
Insertion temp. Pt100 with pressure |
PCT-1 |
No |
|||
Insertion temp.Pt100 for small pipe D |
SCT-1 |
<DN50 |
Yes |
Industries
Applications
Model Selection
I |
Model |
|
|
|
|
|
|
|
|
|
YF |
Electromagnetic flowmeter |
|||||||
|
TF |
Turbine |
|||||||
|
VF |
Votex |
|||||||
|
LX |
Vane wheel |
|||||||
|
T |
Ultrasonic |
|||||||
|
|
E/F display mode |
E: compact/local display, F: remote display |
||||||
|
|
|
Pipe Dia |
Type (mm) |
|||||
|
|
|
xxxx |
10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 |
|||||
|
|
|
Code |
Accuracy |
|||||
|
|
|
1 |
+ 0.5% FS |
|||||
|
|
|
2 |
+ 1.0% FS |
|||||
|
|
|
3 |
+ 0.2% FS |
|||||
|
|
|
|
Code |
Type |
||||
|
|
|
|
N |
Converter: 12 / 24 VDC, pulse output |
||||
|
|
|
|
A |
Transmitter: 24VDC, 4-20mA outpt |
||||
|
|
|
|
B |
Intelligent, Lion battery, no local display |
||||
|
|
|
|
G |
Smart, local display, 4-20mA output |
||||
|
|
|
|
C1 |
Smart, local display, RS485 |
||||
|
|
|
|
C2 |
Smart, local display, HART |
||||
|
|
|
|
|
Code |
Type |
|||
|
|
|
|
|
S |
Carbon steel housing |
|||
|
|
|
|
|
L |
Stainless steel housing |
|||
|
|
|
|
|
G |
High pressure housing |
|||
|
|
|
|
|
HL |
316L electrode |
|||
|
|
|
|
|
HTi |
Titanium electrode |
|||
|
|
|
|
|
HTa |
Tantlum electrode |
|||
|
|
|
|
|
HC |
Hastelloy-C electrode |
|||
|
|
|
|
|
L1 |
Liquid media |
|||
|
|
|
|
|
L2 |
Gas media |
|||
|
|
|
|
|
P |
Pressure compensation |
|||
|
|
|
|
|
T |
Temperature compensation |
|||
|
|
|
|
|
PT |
Pressure&Temp. Compensation |
|||
|
|
|
|
|
F |
PTFE liner |
|||
|
|
|
|
|
X |
Rubber liner |
|||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrode, liquid media meter, PTFE liner |
Competitive Advantage:
Calibration
Work shop
Contact Person: Mr. Murphy
Tel: 0086-138 1661 4405
Fax: 86-21-31105302