All Flow Technology
Place of Origin: | China |
Brand Name: | Purescience |
Certification: | ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429 |
Model Number: | EMF80 |
Minimum Order Quantity: | 5 sets |
---|---|
Price: | negotiable |
Packaging Details: | carton |
Delivery Time: | 3 weeks |
Payment Terms: | T/T, L/C, Western Union |
Supply Ability: | 500 sets per month |
Product Name: | Sewage Magnetic Flow Meter | Flow Transmitter: | Remote Or Integral |
---|---|---|---|
Liner Material: | Hard Rubber, PTFE | Flow Velocity Range: | 1-15 M/s |
Pressure Rating: | PN16, PN25, PN40 Mpa | Accuracy: | 0.5% R |
Pipe Dia.: | DN25-DN300 | Connect Port: | Flange |
Enclosure Protection: | IP68 | Power Supply: | 100-240 VAC / 18-36 VDC |
High Light: | water flow meter,ultrasonic water meter |
PTFE liner: electromagnetic flow meter for slurry flow meter, Output: analogue, pulse
General introduction:
An electromagnetic flow metering system, combining both a flow sensor and transmitter into one convenient package. It incorporates rugged carbon steel construction with ANSI flanges creating a versatile, user-friendly flow metering system for general purpose applications involving clean, sanitary, dirty, corrosive and abrasive liquids. The flow sensor is IP68 rated for protection from dust and low pressure water jets.
Application
Agricultural, irrigation, boiler feedwater, clean room, clean water, concrete , coolant, HVAC / R system monitoring, residential water monitoring, utilities, waste water, grey water
Grounding
From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.
Key Features
Technical data
Product name |
Electromagnetic flowmeter |
||
Product type |
Local|compact display |
Remote display |
Signal converter |
Model |
IYF-E |
IYF-F |
IRT |
Pipe Diameter (mm) |
DN10-DN2000 |
||
Power supply |
100-240 VAC / 18-36 VDC |
||
Accuracy |
+ 0.5% |
+ 0.5% |
+ 0.5% |
Power consumption |
<6w |
<6w |
<6w |
Enclosure rating |
IP65 |
IP68 |
IP65 |
Liquid temperature |
-25-120℃ |
-25-120℃ |
-25-120℃ |
Ambient temperature |
-25-50℃ |
-25-50℃ |
-25-50℃ |
Relative humidity |
10-90% |
10-90% |
10-90% |
Meter ratio |
1:100 |
1:100 |
1:100 |
Flow direction |
Bi-direction flow |
Bi-direction flow |
Bi-direction flow |
Communication |
RS485 / Bacnet |
RS485 / Bacnet |
RS485 / Bacnet |
Signal Output |
4-20mA/Pulse/Frequency |
4-20mA/Pulse/Frequency |
4-20mA/Pulse/Frequency |
Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Selection guide
I |
Model |
|
|
|
|
|
|
|
|
|
YF |
Electromagnetic flowmeter |
|||||||
|
TF |
Turbine |
|||||||
|
VF |
Votex |
|||||||
|
LX |
Vane wheel |
|||||||
|
T |
Ultrasonic |
|||||||
|
|
E/F display mode |
E: compact/local display, F: remote display |
||||||
|
|
|
Pipe Dia |
Type (mm) |
|||||
|
|
|
xxxx |
15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 |
|||||
|
|
|
Code |
Accuracy |
|||||
|
|
|
1 |
+ 0.5% FS |
|||||
|
|
|
2 |
+ 1.0% FS |
|||||
|
|
|
3 |
+ 0.2% FS |
|||||
|
|
|
|
Code |
Type |
||||
|
|
|
|
N |
Converter: 12 / 24 VDC, pulse output |
||||
|
|
|
|
A |
Transmitter: 24VDC, 4-20mA outpt |
||||
|
|
|
|
B |
Intelligent, Lion battery, no local display |
||||
|
|
|
|
G |
Smart, local display, 4-20mA output |
||||
|
|
|
|
C1 |
Smart, local display, RS485 |
||||
|
|
|
|
C2 |
Smart, local display, HART |
||||
|
|
|
|
|
Code |
Type |
|||
|
|
|
|
|
S |
Carbon steel housing |
|||
|
|
|
|
|
L |
Stainless steel housing |
|||
|
|
|
|
|
G |
High pressure housing |
|||
|
|
|
|
|
HL |
316L electrode |
|||
|
|
|
|
|
HTi |
Titanium electrode |
|||
|
|
|
|
|
HTa |
Tantlum electrode |
|||
|
|
|
|
|
HC |
Hastelloy-C electrode |
|||
|
|
|
|
|
L1 |
Liquid media |
|||
|
|
|
|
|
L2 |
Gas media |
|||
|
|
|
|
|
P |
Pressure compensation |
|||
|
|
|
|
|
T |
Temperature compensation |
|||
|
|
|
|
|
PT |
Pressure&Temp. Compensation |
|||
|
|
|
|
|
F |
PTFE liner |
|||
|
|
|
|
|
X |
Rubber liner |
|||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner |
Pipe Diameter, flow volume and product dimension
Dia |
Flow volume (m3/h) |
Product dimension (mm) |
|||||
(mm) |
Normal |
Min |
Max |
L |
D |
H |
H1 |
15 |
1.5 |
0.06 |
9.5 |
150 |
95 |
272 |
254 |
20 |
2.5 |
0.11 |
16.9 |
105 |
277 |
254 |
|
25 |
3.5 |
0.18 |
26.5 |
115 |
283 |
254 |
|
32 |
6 |
0.29 |
43.6 |
140 |
297 |
270 |
|
40 |
10 |
0.45 |
67.8 |
150 |
307 |
280 |
|
50 |
15 |
0.71 |
106.0 |
200 |
165 |
318 |
294 |
65 |
25 |
1.19 |
179.1 |
185 |
337 |
313 |
|
80 |
40 |
1.81 |
271.4 |
200 |
352 |
326 |
|
100 |
60 |
2.83 |
424.1 |
250 |
220 |
371 |
344 |
125 |
100 |
4.42 |
665 |
250 |
401 |
372 |
|
150 |
135 |
6.36 |
954 |
300 |
285 |
431 |
403 |
200 |
250 |
11.3 |
1696 |
350 |
340 |
486 |
460 |
250 |
375 |
17.66 |
2650 |
400 |
395 |
547 |
511 |
300 |
540 |
25.43 |
3817 |
450 |
445 |
597 |
565 |
350 |
735 |
34.62 |
5195 |
505 |
657 |
620 |
|
400 |
960 |
45.22 |
6785 |
500 |
565 |
717 |
675 |
450 |
1200 |
57.23 |
8588 |
550 |
615 |
757 |
727 |
500 |
1500 |
70 |
10602 |
600 |
670 |
817 |
782 |
600 |
2160 |
100 |
15268 |
780 |
917 |
782 |
|
700 |
2950 |
138 |
20781 |
700 |
895 |
1027 |
1068 |
800 |
3850 |
180 |
27100 |
800 |
1015 |
1137 |
1157 |
Industrial applications
Chemical |
Food & beverage |
Paper mill |
Metallurgy |
Environment protection |
Hydraulic |
Mining |
Stainless |
Petroleum |
Pharmacy |
Air conditioner |
Effluent treatment plant |
Seawater desalination |
Pharmacy |
Water treatment |
Competitive advantage
Contact Person: Mr. Murphy
Tel: +8613816614405