Send Message
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMagnetic Flow Meter

Ip65 Water Flow Meter Electromagnetic Dn25 - Dn300 With Flanges Port Connection

Ip65 Water Flow Meter Electromagnetic Dn25 - Dn300 With Flanges Port Connection

  • Ip65 Water Flow Meter Electromagnetic Dn25 - Dn300 With Flanges Port Connection
Ip65 Water Flow Meter Electromagnetic Dn25 - Dn300 With Flanges Port Connection
Product Details:
Place of Origin: China
Brand Name: Purescience
Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Model Number: YF-F80
Payment & Shipping Terms:
Minimum Order Quantity: 5 sets
Price: negotiable
Packaging Details: carton
Delivery Time: 3 weeks
Payment Terms: T/T, L/C, Western Union
Supply Ability: 500 sets per month
Contact Now
Detailed Product Description
Application: Utility Water Flow Meter Electrode: 316L / Hasteloy-C / Ti / Ta / Pt100
Liner Material: NR / CR / PTFE Liner Flow Velocity Range: 1-15 M/s
Pressure Rating: PN16, PN25, PN40 Mpa Accuracy: +/1 0.5% R
Pipe Dia.: DN25-DN300 Connect Port: Flange
Enclosure Protection: IP65 Power Supply: 100-240 VAC / 18-36 VDC
Highlight:

water flow meter

,

ultrasonic water meter

Utility water flow meters by magnetic flowmeter, PTFE liner, remote display, PN16

 

Product Description

The electromagnetic flow meter, sizes from 1 to 24 inches. It has no parts to obstruct flow resulting in no pressure loss and the 0.75% accuracy is not affected by temperature, pressure, viscosity, density or flow profile. With no moving parts, practically no maintenance is required. The chloroprene rubber sensor liner is suitable for liquid temperatures from -13 to 176°F and is compatible with most water-based fluids and many chemicals. Contact us for additional chemical compatibility information.

 

Pipe Diameter, flow volume and product dimension

Dia Flow volume (m3/h) Product dimension (mm)
(mm) Normal Min Max L D H H1
15 1.5 0.06 9.5 150 95 272 254
20 2.5 0.11 16.9 105 277 254
25 3.5 0.18 26.5 115 283 254
32 6 0.29 43.6 140 297 270
40 10 0.45 67.8 150 307 280
50 15 0.71 106.0 200 165 318 294
65 25 1.19 179.1 185 337 313
80 40 1.81 271.4 200 352 326
100 60 2.83 424.1 250 220 371 344
125 100 4.42 665 250 401 372
150 135 6.36 954 300 285 431 403
200 250 11.3 1696 350 340 486 460
250 375 17.66 2650 400 395 547 511
300 540 25.43 3817 450 445 597 565
350 735 34.62 5195 505 657 620
400 960 45.22 6785 500 565 717 675
450 1200 57.23 8588 550 615 757 727
500 1500 70 10602 600 670 817 782
600 2160 100 15268 780 917 782
700 2950 138 20781 700 895 1027 1068
800 3850 180 27100 800 1015 1137 1157

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ip65 Water Flow Meter Electromagnetic Dn25 - Dn300 With Flanges Port Connection 0

Industrial applications

Chemical Food & beverage Paper mill
Metallurgy Environment protection Hydraulic
Mining Stainless Petroleum
Pharmacy Air conditioner Effluent treatment plant
Seawater desalination Pharmacy Water treatment

 

 

 

 

 

 

 

Technical data

Product name

Electromagnetic flowmeter

Product type

Local|compact display

Remote display

Signal converter

Model

IYF-E

IYF-F

IRT

Pipe Diameter (mm)

DN10-DN2000

Power supply

100-240 VAC / 18-36 VDC

Accuracy

+ 0.5% 

+ 0.5%

+ 0.5%

Power consumption

<6w

<6w

<6w

Enclosure rating

IP65

IP68

IP65

Liquid temperature

-25-120℃

-25-120℃

-25-120℃

Ambient temperature

-25-50℃

-25-50℃

-25-50℃

Relative humidity

10-90%

10-90%

10-90%

Meter ratio

1:100

1:100

1:100

Flow direction

Bi-direction flow

Bi-direction flow

Bi-direction flow

Communication

RS485 / Bacnet

RS485 / Bacnet

RS485 / Bacnet

Signal Output

4-20mA/Pulse/Frequency

4-20mA/Pulse/Frequency

4-20mA/Pulse/Frequency

 

Features

  • Virtually no pressure loss
  • Suitable to meter for wide range of conductive liquid media
  • No Moving Parts
  • Flanges port connection
  • RS485 Standard
  • Suitable for Pipes diameter p to 2000 mm 
  • Large meter ratio
  • High Accuracy
  • 4 to 20 mA / Frequency / Pulse output

Model selection

Applicable metering liquid:

  • Conductive liquid media, conductivity > 5 µS/ cm
  • Various Conductive aqueous solutions, water solutions, acid & caustics
  • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
    water, effluent, fibrous, viscous, paper mill, food & beverage

Non-applicable metering medial

  • Industrial gas, compressed air, steam, or liquid with large content of gas
  • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure 
    water, clean gas, etc. 

Notice on the selection of local type and remote type: 

Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select 
remote type in the following conditions:

  • Ambient temperature or converter display sunshine temperature is over 60 ℃
  • High humidity or corrosive air existed
  • Serious pipe vibration 
  • Magnetic meter need be suspended or submersible, uneasily read out
  • Other abrasive condition

I

Model

 

 

 

 

 

 

 

 

YF

Electromagnetic flowmeter

 

TF

Turbine

 

VF

Votex

 

LX

Vane wheel

 

T

Ultrasonic

 

 

E/F display mode

E: compact/local display, F: remote display

 

 

 

Pipe Dia

Type (mm)

 

 

 

xxxx

15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 

500, 600, 800, 1000

 

 

 

Code

Accuracy

 

 

 

1

+ 0.5% FS

 

 

 

2

+ 1.0% FS

 

 

 

3

+ 0.2% FS

 

 

 

 

Code

Type

 

 

 

 

N

Converter: 12 / 24 VDC, pulse output

 

 

 

 

A

Transmitter: 24VDC, 4-20mA outpt

 

 

 

 

B

Intelligent, Lion battery, no local display

 

 

 

 

G

Smart, local display, 4-20mA output

 

 

 

 

C1

Smart, local display, RS485

 

 

 

 

C2

Smart, local display, HART

 

 

 

 

 

Code

Type

 

 

 

 

 

S

Carbon steel housing

 

 

 

 

 

L

Stainless steel housing

 

 

 

 

 

G

High pressure housing

 

 

 

 

 

HL

316L electrode

 

 

 

 

 

HTi

Titanium electrode

 

 

 

 

 

HTa

Tantlum electrode

 

 

 

 

 

HC

Hastelloy-C electrode

 

 

 

 

 

L1

Liquid media

 

 

 

 

 

L2

Gas media

 

 

 

 

 

P

Pressure compensation

 

 

 

 

 

T

Temperature compensation

 

 

 

 

 

PT

Pressure&Temp. Compensation

 

 

 

 

 

F

PTFE liner

 

 

 

 

 

X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, 

smart, 4-20mA outpt, RS485,  316L electrodes, liquid media meter, PTFE liner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Competitive advantage

  • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Contact Details
Shanghai Xunhui Environment Technology Co., Ltd.

Contact Person: Mr. Murphy

Tel: 0086-138 1661 4405

Fax: 86-21-31105302

Send your inquiry directly to us (0 / 3000)

Best Products
Other Products