    Product Details:

    Place of Origin: China
    Brand Name: Purescience
    Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
    Model Number: YE-EF800

    Payment & Shipping Terms:

    Minimum Order Quantity: 5 sets
    Price: USD250-USD900
    Packaging Details: carton
    Delivery Time: 3 weeks
    Supply Ability: 500 sets per month
    Contact Now
    Detailed Product Description
    Product Name: Electromagnetic Flowmeters Material Of Wet Part: NR / CR / PTFE Liner
    MOC Of Sensor Body: 316L / Hastelloy-C, Ti, Ta, Pt100 Flow Velocity Range: 1-15 M/s
    Pressure Rating: PN16 | 1.6 Mpa Accuracy: +/1 0.5% R
    Pipe Dia.: DN25-DN800 Connect Port: Flange
    Enclosure Protection: IP65 Power Supply: 100-240 VAC / 18-36 VDC
    High Light:

    liquid flow meter

    ,

    ultrasonic water meter

    Electromagnetic flow meters to determine flow of water | acids | caustic | slurry and any conductive liquids in pipe

     

    Accuracy 

    Pipe Dia (mm)

    Velocity (m/s)

    Accuracy

    3-20

    <0.3

    + 0.25% FS

    0.3-1

    + 1.0% Readout

    1-15

    + 0.25% Readout

    25-600

    0.1-0.3

    + 0.25% FS

    0.3-1

    + 0.5% Readout

    1-15

    + 0.3% Readout

    700-3000

    <0.3

    + 0.25% FS

    0.3-1

    + 1.0% Readout

    1-15

    + 0.25% Readout

     

     

     

     

     

     

     

     

     

     

     

     

     

    Grounding

    From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.

     

    Technical data

    Product name

    Electromagnetic flowmeter

    Product type

    Local|compact display

    Remote display

    Signal converter

    Model

    IYF-E

    IYF-F

    IRT

    Pipe Diameter (mm)

    DN10-DN2000

    Power supply

    100-240 VAC / 18-36 VDC

    Accuracy

    + 0.5% 

    + 0.5%

    + 0.5%

    Power consumption

    <6w

    <6w

    <6w

    Enclosure rating

    IP65

    IP68

    IP65

    Liquid temperature

    -25-120℃

    -25-120℃

    -25-120℃

    Ambient temperature

    -25-50℃

    -25-50℃

    -25-50℃

    Relative humidity

    10-90%

    10-90%

    10-90%

    Meter ratio

    1:100

    1:100

    1:100

    Flow direction

    Bi-direction flow

    Bi-direction flow

    Bi-direction flow

    Communication

    RS485 / Bacnet

    RS485 / Bacnet

    RS485 / Bacnet

    Signal Output

    4-20mA/Pulse/Frequency

    4-20mA/Pulse/Frequency

    4-20mA/Pulse/Frequency

     

    Description

    The flanged electromagnetic flowmeter for use in volumetric measurement of conductive fluid, like municipal 

    or industrial water and waste water applications in which propeller meters have typically been used in the past.

    With no moving parts and electrodes designed to discourage fouling, the IYF magmeter require minimal 

    maintenance in applications in which debris or sand would impede propeller meters. There is no rotor to stop 

    turning or bearings to wear out. 
    It’s externally powered with 100-240VAC or 24 VDC. Low power requirements also make it ideal for solar 

    and comparable power sources. Rate and total indication is standard, as is a solid state pulse / frequency / 

    4-20mA output, that allows connection to a data logger. 
    The display housing can be either integrated or remote. A shielded power/pulse output cable with DIN connection 

    is included with the meter. 

     

    Features

    • Virtually no pressure loss
    • Suitable to meter for wide range of conductive liquid media
    • No Moving Parts
    • Flanges port connection
    • RS485 Standard
    • Suitable for Pipes diameter p to 2000 mm 
    • Large meter ratio
    • High Accuracy
    • 4 to 20 mA / Frequency / Pulse output

    Mounting notice

    Flanged Electromagnetic Flow Meters For Conductive Liquids In Pipe 0

    Flanged Electromagnetic Flow Meters For Conductive Liquids In Pipe 1

     

    Model selection

    Applicable metering liquid:

    • Conductive liquid media, conductivity > 5 µS/ cm
    • Various Conductive aqueous solutions, water solutions, acid & caustics
    • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
      water, effluent, fibrous, viscous, paper mill, food & beverage

    Non-applicable metering medial

    • Industrial gas, compressed air, steam, or liquid with large content of gas
    • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure 
      water, clean gas, etc. 

    Notice on the selection of local type and remote type: 

    Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select 
    remote type in the following conditions:

    • Ambient temperature or converter display sunshine temperature is over 60 ℃
    • High humidity or corrosive air existed
    • Serious pipe vibration 
    • Magnetic meter need be suspended or submersible, uneasily read out
    • Other abrasive condition

    I

    Model

     

     

     

     

     

     

     

     

    YF

    Electromagnetic flowmeter

     

    TF

    Turbine

     

    VF

    Votex

     

    LX

    Vane wheel

     

    T

    Ultrasonic

     

     

    E/F display mode

    E: compact/local display, F: remote display

     

     

     

    Pipe Dia

    Type (mm)

     

     

     

    xxxx

    15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 

    500, 600, 800, 1000

     

     

     

    Code

    Accuracy

     

     

     

    1

    + 0.5% FS

     

     

     

    2

    + 1.0% FS

     

     

     

    3

    + 0.2% FS

     

     

     

     

    Code

    Type

     

     

     

     

    N

    Converter: 12 / 24 VDC, pulse output

     

     

     

     

    A

    Transmitter: 24VDC, 4-20mA outpt

     

     

     

     

    B

    Intelligent, Lion battery, no local display

     

     

     

     

    G

    Smart, local display, 4-20mA output

     

     

     

     

    C1

    Smart, local display, RS485

     

     

     

     

    C2

    Smart, local display, HART

     

     

     

     

     

    Code

    Type

     

     

     

     

     

    S

    Carbon steel housing

     

     

     

     

     

    L

    Stainless steel housing

     

     

     

     

     

    G

    High pressure housing

     

     

     

     

     

    HL

    316L electrode

     

     

     

     

     

    HTi

    Titanium electrode

     

     

     

     

     

    HTa

    Tantlum electrode

     

     

     

     

     

    HC

    Hastelloy-C electrode

     

     

     

     

     

    L1

    Liquid media

     

     

     

     

     

    L2

    Gas media

     

     

     

     

     

    P

    Pressure compensation

     

     

     

     

     

    T

    Temperature compensation

     

     

     

     

     

    PT

    Pressure&Temp. Compensation

     

     

     

     

     

    F

    PTFE liner

     

     

     

     

     

    X

    Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, 

    smart, 4-20mA outpt, RS485,  316L electrodes, liquid media meter, PTFE liner

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Pipe Diameter, flow volume and product dimension

    Dia

    Flow volume (m3/h)

    Product dimension (mm)

    (mm)

    Normal

    Min

    Max

    L

    D

    H

    H1

    15

    1.5

    0.06

    9.5

    150

    95

    272

    254

    20

    2.5

    0.11

    16.9

    105

    277

    254

    25

    3.5

    0.18

    26.5

    115

    283

    254

    32

    6

    0.29

    43.6

    140

    297

    270

    40

    10

    0.45

    67.8

    150

    307

    280

    50

    15

    0.71

    106.0

    200

    165

    318

    294

    65

    25

    1.19

    179.1

    185

    337

    313

    80

    40

    1.81

    271.4

    200

    352

    326

    100

    60

    2.83

    424.1

    250

    220

    371

    344

    125

    100

    4.42

    665

    250

    401

    372

    150

    135

    6.36

    954

    300

    285

    431

    403

    200

    250

    11.3

    1696

    350

    340

    486

    460

    250

    375

    17.66

    2650

    400

    395

    547

    511

    300

    540

    25.43

    3817

    450

    445

    597

    565

    350

    735

    34.62

    5195

    505

    657

    620

    400

    960

    45.22

    6785

    500

    565

    717

    675

    450

    1200

    57.23

    8588

    550

    615

    757

    727

    500

    1500

    70

    10602

    600

    670

    817

    782

    600

    2160

    100

    15268

    780

    917

    782

    700

    2950

    138

    20781

    700

    895

    1027

    1068

    800

    3850

    180

    27100

    800

    1015

    1137

    1157

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Industrial applications

    Chemical

    Food & beverage

    Paper mill

    Metallurgy

    Environment protection

    Hydraulic

    Mining

    Stainless

    Petroleum

    Pharmacy

    Air conditioner

    Effluent treatment plant

    Seawater desalination

    Pharmacy

    Water treatment

     

     

     

     

     

     

    Competitive advantage

    • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Process control

    Flanged Electromagnetic Flow Meters For Conductive Liquids In Pipe 2

    Calibration equipment

    Flanged Electromagnetic Flow Meters For Conductive Liquids In Pipe 3

     

    Contact Details
    Shanghai Xunhui Environment Technology Co., Ltd.

    Contact Person: Mr. Murphy

    Tel: +8613816614405

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products