Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsUltrasonic Flow Meters

Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

    • Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine
    • Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine
    • Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine
  • Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

    Product Details:

    Place of Origin: China
    Brand Name: Purescience
    Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
    Model Number: YE-TUF2000FP

    Payment & Shipping Terms:

    Minimum Order Quantity: 5 sets
    Price: USD150-USD900
    Packaging Details: carton
    Delivery Time: 3 weeks
    Supply Ability: 500 sets per month
    Contact Now
    Detailed Product Description
    Product Name: Ultrasonic Flowmeters Type: Inline | Pipe Type
    Accuracy: + / - 1%FS Operation: Key Boards
    Output Signal: 4-20 MA / OCT Pulse / Relay Input: 3-way 4-20 MA (temperature, Pressure And Level)
    Communication: RS485 / Modbus Power Supply: 8-36 VDC / 10-30 VAC
    Pipe Diameter: 15 Mm - 6000mm Pipe Mount Material: Weld Steel, Stainless Steel, Cast Iron, Copper / Brass, Cement Pipe, Aluminum
    High Light:

    magnetic flowmeter

    ,

    water flow meter

    Fixed Inline ultrasonic flowmeters by transit time multi-liquid velocity determine for slurry | effluent | sewage

     

    General of ultrasonic flow meters

    The UFM Ultrasonic flowmeters  can determine the velocity of a fluid flowing in a pipe by sound waves. When it's in no flow conditions, an ultrasonic wave's frequencies are transmitted into a pipe and its reflections from the fluid are the same. When it's under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect. When liquid media moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave and its reflections to determine the flow rate.

    The transit time type ultrasonic flowmeters can give and receive ultrasonic waves between the transducers in both the upstream and downstream in the pipe. While it's under no flow conditions, it takes the same time to travel upstream and downstream between the transducers. While it's under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave. When the fluid moves faster, the difference between the upstream and downstream times increases. The transmitter processes upstream and downstream times to determine the flow rate.

     

    Data sheet

    Accuracy                                                           <1%

    Flow rate                                                           0 - 10m/s, bi-direction

    Pipe diameter                                                    DN32 - DN6000 mm

    Liquid temperature                                            -30℃ - 160℃

    Liquid type                                                        water, sea water, sewage, effluent, oil, alcohol, any single liquid that can

                                                                               transmit ulstrasonic wave

    Pipe material                                                     stainless steel, cast iron, copper, PVC, aluminum, fiber glass steel

    Output                                                               one way 4-20mA, one way OCT pulse, one way replay

    Input                                                                  three way 4-20mA, PT1000 platinum resistor for heat measurement

    Communication                                                RS485, MODBUS

    Data storage                                                      SD card

    Power supply                                                    DC8-36V / AC85-264V

    Protection                                                         IP65 (main body), IP68 (transducer)

    Humidity                                                          <85% RH

    Ambient temperature                                       -20℃ - 60℃

     

    Description:

    The ultrasonic flowmeter is available with pipe type, clamp on and other options, it's designed for linear and bi-directional volumetric flow measurement of liquid. The measured flow datas can be output by standard analog or pulse or frequency. Through HMI user friendly operator interface, the unit can be set up for a wide range of applications. Next to actual volumetric flow measurement, the unit can be configured to perform flow totalization ( plus, minus, or sum). Measurement and output of the liquid sonic velocity can be configured too.  

     

    Optionally the unit can be set to perform one of the following additional functions:

    • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
    • Batch function
    • Heat function, combining T1, T2 and volume

    Metering Diagram 

    Flow measurement                                                Heat measurement

    Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine 0

    Reference chart

    Type

    Model

    Pipe dia (mm)

    Temperature

    Dimension (mm)

    Clamp on

    TS-2

    DN15-100

    -30-90℃

    45x25x32

    TM-1

    DN50-700

    -30-90℃

    64x39x44

    TL-1

    DN300-6000

    -30-90℃

    97x54x53

    Clamp on (high temperature)

    TS-2-HT

    DN15-100

    -30-90℃

    45x25x32

    TM-1-HT

    DN50-700

    -30-90℃

    64x39x44

    TL-1-HT

    DN300-6000

    -30-90℃

    97x54x53

    Insertion type

    TC-1

    DN80-6000

    -30-90℃

    190x80x55

    TC-2(lengthen)

    DN80-6000

    -30-90℃

    335x80x55

    Pipe type

    G3 (π type)

    DN15-25

    -30-160℃

     

    G2

    DN32/DN40

    -30-160℃

     

    G3

    DN50-6000

    -30-160℃

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Optional temperature transducer

    Specification

    Model

    Dia

    Temp.

    Water cut

    Accuracy

    Clamp-on temp. transducer Pt100

    CT-1

    >DN50

    -40-160℃

    No

    100+ 0.8℃

    Insertion temp. Transducer Pt100

    TCT-1

    Yes

    Insertion temp. Pt100 with pressure

    PCT-1

    No

    Insertion temp.Pt100 for small pipe D

    SCT-1

    <DN50

    Yes

     

     

     

     

     

     

    Industries

    • Chemicals
    • Petrochemicals
    • Oil & Gas
    • Heating, Ventilation & Air Conditioning (HVAC)
    • Power Plants
    • Water treatment

    Liquid type

    • Metering of cooling water
    • Demineralisedwater
    • Control of batching and blending operations
    • Mass flow measurement
    • Allocation measurement
    • District heating
    • Irrigation
    • Energy measurement

    Model Selection

    I

    Model

     

     

     

     

     

     

     

     

    YF

    Electromagnetic flowmeter

     

    TF

    Turbine

     

    VF

    Votex

     

    LX

    Vane wheel

     

    T

    Ultrasonic

     

     

    E/F display mode

    E: compact/local display, F: remote display

     

     

     

    Pipe Dia

    Type (mm)

     

     

     

    xxxx

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 

    400, 500, 600, 800, 1000

     

     

     

    Code

    Accuracy

     

     

     

    1

    + 0.5% FS

     

     

     

    2

    + 1.0% FS

     

     

     

    3

    + 0.2% FS

     

     

     

     

    Code

    Type

     

     

     

     

    N

    Converter: 12 / 24 VDC, pulse output

     

     

     

     

    A

    Transmitter: 24VDC, 4-20mA outpt

     

     

     

     

    B

    Intelligent, Lion battery, no local display

     

     

     

     

    G

    Smart, local display, 4-20mA output

     

     

     

     

    C1

    Smart, local display, RS485

     

     

     

     

    C2

    Smart, local display, HART

     

     

     

     

     

    Code

    Type

     

     

     

     

     

    S

    Carbon steel housing

     

     

     

     

     

    L

    Stainless steel housing

     

     

     

     

     

    G

    High pressure housing

     

     

     

     

     

    HL

    316L electrode

     

     

     

     

     

    HTi

    Titanium electrode

     

     

     

     

     

    HTa

    Tantlum electrode

     

     

     

     

     

    HC

    Hastelloy-C electrode

     

     

     

     

     

    L1

    Liquid media

     

     

     

     

     

    L2

    Gas media

     

     

     

     

     

    P

    Pressure compensation

     

     

     

     

     

    T

    Temperature compensation

     

     

     

     

     

    PT

    Pressure&Temp. Compensation

     

     

     

     

     

    F

    PTFE liner

     

     

     

     

     

    X

    Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F, 

    Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, 

    RS485, 316L electrode, liquid media meter, PTFE liner

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Competitive Advantage:

    • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
    • CE approval
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Calibration

    Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine 1

    Work shop

    Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine 2

    Contact Details
    Shanghai Xunhui Environment Technology Co., Ltd.

    Contact Person: Mr. Murphy

    Tel: +8613816614405

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products